Barcode verification is the process of confirming that a barcode meets its specification: that it's printed well enough to scan reliably, and that it contains the right data. Print quality is graded against international standards, ISO/IEC 15416 for linear barcodes and ISO/IEC 15415 for 2D codes such as Data Matrix. Data accuracy is checked against the approved values.

Most barcode guides focus on the first half: print grades, scan parameters, and verifier hardware. In regulated packaging, the second half matters just as much. A perfectly printed Data Matrix that encodes the wrong batch number or expiry date is a compliance failure, and no print grade will catch it.

This guide covers both: how grading works, what each industry's rules require, and how to build a verification process that catches the errors print grading misses.

Scanning, Grading, and Verification Aren't the Same Thing

These three terms are often used interchangeably, but they answer different questions:

  • Scanning answers: can a reader decode this barcode right now? A barcode that scans once in good conditions can still fail in the field.
  • Grading answers: how well is this barcode printed? It measures print quality against ISO/IEC parameters under controlled conditions, predicting whether it will scan reliably across different scanners and environments.
  • Verification answers: does this barcode meet its full specification? That includes a sufficient grade, and also correct data, the right structure, and a match with the human-readable text printed next to it.

A barcode can pass the first two and still fail the third.

How Barcode Grading Works

ISO/IEC 15416: Linear Barcodes

ISO/IEC 15416 sets out how to grade the print quality of linear (1D) barcodes, such as EAN-13, UPC-A, GS1-128, and Code 128. A verifier takes multiple scans across the barcode and measures parameters including symbol contrast, edge contrast, modulation, defects, and decodability.

ISO/IEC 15415: 2D Codes

ISO/IEC 15415 does the same for 2D codes, including Data Matrix, QR codes, and PDF417. It measures parameters such as symbol contrast, modulation, axial and grid non-uniformity, unused error correction, and fixed pattern damage, and combines them into an overall grade.

The Grading Scale

Both standards use the same scale. The overall grade is the lowest-scoring parameter, so a single weakness brings the whole grade down.

Letter gradeNumeric gradeWhat it means
A3.5 to 4.0Excellent print quality
B2.5 to 3.4Good print quality
C1.5 to 2.4Acceptable for many applications, and the EU benchmark for pharma Data Matrix codes
D0.5 to 1.4Poor; may not scan reliably
FBelow 0.5Fail

A grade is usually reported alongside the measurement conditions, such as the aperture size and light wavelength used, because the same barcode can grade differently under different conditions. Specifications from GS1 and regulators state the conditions along with the minimum grade.

One practical point: formal ISO grading is done on the printed barcode, with a calibrated verifier, under controlled conditions. Checks on the digital artwork file can confirm the data, structure, size, and quiet zones before print, but the final print grade has to be measured on the physical output.

What Each Industry Requires

IndustryMain barcodePrint qualityData to verify
Pharma (EU)Data Matrix with unique identifierAt least 1.5 under ISO/IEC 15415 is presumed compliantProduct code, serial number, batch, expiry, and matching human-readable text
Pharma (US)Linear NDC barcode; DSCSA 2D Data Matrix on each packageNo numeric grade in the rules; GS1 guidance typically followedNDC, serial number, lot, expiry
Medical devicesUDI carrier (linear or Data Matrix)Must be readable in normal use; issuing agency standards applyUDI-DI and UDI-PI, consistent across packaging levels
FMCG/CPGEAN/UPC at retail; GS1-128 on casesGS1 General Specifications by applicationGTIN and any batch, date, or weight data

Pharma (EU)

Under the EU's safety features rules, Delegated Regulation (EU) 2016/161, most prescription medicines carry a unique identifier in a Data Matrix. The regulation sets a specific print quality benchmark: a quality of printing rated at least 1.5 under ISO/IEC 15415 is presumed to meet the requirement. Manufacturers must also print key data elements of the unique identifier in human-readable form.

It goes further than print quality. The manufacturer placing the safety features must verify, before release, that the Data Matrix complies, is readable, and contains the correct information, as the European Commission's Q&A on safety features confirms. Verification of the data, not just the print, is a regulatory requirement.

Pharma (US)

Most prescription drug labels need a linear barcode containing the NDC under 21 CFR 201.25, and DSCSA requires a product identifier in a 2D Data Matrix on each package. US rules don't set a specific numeric grade the way the EU does, but the barcodes still need to scan reliably across the supply chain, so manufacturers typically follow GS1 print quality guidance. The move to a 12-digit NDC format will change the data encoded in every NDC barcode over time.

Medical Devices

Under both EU MDR and FDA rules, devices carry a Unique Device Identifier in both machine-readable (AIDC) and human-readable form. The UDI must be readable in normal use, and the issuing agencies' standards, typically GS1, set the print quality expectations. The biggest risk for devices is usually data consistency across packaging levels rather than print grade, as we cover in our UDI Labeling Requirements guide.

FMCG/CPG

Retail barcodes (EAN/UPC) and logistics barcodes (GS1-128) follow the GS1 General Specifications, which set symbol size, quiet zone, and minimum print quality for each application. Retailers can reject or charge back shipments with barcodes that don't scan. The shift to 2D barcodes at retail point of sale is covered in our GS1 Sunrise 2027 guide.

Why a Good Grade Isn't Enough

A print grade tells you a barcode will scan. It doesn't tell you what it will say when it does. These are the errors that pass grading and still cause compliance problems:

Wrong data encoded. A GTIN, NDC, or product code from a previous version or a similar product, a batch number or expiry date copied from the wrong source, or a transposed digit that still produces a valid-looking code.

Human-readable text that doesn't match. The printed text next to the barcode shows one value, while the barcode encodes another. This often happens when the text and the barcode are updated separately.

Incorrect data structure. In GS1 barcodes, each piece of data is labeled with an Application Identifier, such as (01) for the GTIN, (10) for the batch, and (17) for the expiry date. A barcode with the wrong identifier, a missing separator, or a date in the wrong format can scan and grade well while being read incorrectly downstream.

Inconsistency across packaging levels. The unit pack, carton, and case each carry related but different identifiers. A change reaching one level but not another is a common source of non-conformities, in devices especially.

An out-of-date barcode on a reprint. An older artwork file used for a reprint can carry a barcode that was correct once, but isn't anymore.

None of these show up in a print grade. They're caught by comparing the barcode's decoded data against the approved values, and against the human-readable text, every time the artwork changes.

Building a Barcode Verification Process

1. Verify the data at the artwork stage. Before anything is printed, decode every barcode in the artwork file and compare the data against the approved values, the data structure, and the human-readable text. This is where most barcode errors can be caught, and where fixing them is cheapest.

2. Check the design parameters. Confirm symbol size, quiet zones, and placement meet the relevant specification before print.

3. Grade the printed output. Measure print quality on the physical barcode, against the grade and conditions your specification requires, such as the EU's 1.5 benchmark for pharma Data Matrix codes. Keeping this step in the same system as your artwork checks means the grade is recorded alongside the rest of the release evidence.

4. Verify every packaging level. Check unit, carton, and case barcodes against each other, not just individually.

5. Document the results. Record what was verified, against which approved values, with which result, and tie it to the specific artwork version, as part of the audit trail for release.

6. Re-verify after every change. Any artwork change, even one that doesn't seem to touch the barcode, can affect it. The Artwork Approval Process Checklist covers where barcode checks fit in the wider workflow.

Frequently Asked Questions

How are barcodes graded?Under ISO/IEC 15416 for linear barcodes and ISO/IEC 15415 for 2D codes. A verifier measures a set of print quality parameters under controlled conditions and gives an overall grade from A (4.0) to F (0.0), based on the lowest-scoring parameter.

What barcode grade is required for pharmaceuticals?In the EU, a Data Matrix carrying the unique identifier with a print quality of at least 1.5 under ISO/IEC 15415 is presumed to meet the requirement. US rules don't set a numeric grade, but barcodes must scan reliably, so manufacturers typically follow GS1 guidance.

What's the difference between a barcode scanner and a barcode verifier?A scanner reads the barcode. A verifier grades its print quality against ISO/IEC standards under controlled, calibrated conditions.

Does a good barcode grade mean the barcode is correct?No. The grade measures print quality, not content. A well-printed barcode can still contain the wrong product code, batch, or expiry date, so the decoded data needs to be checked against the approved values as well.

Content Compare decodes every barcode in your artwork and checks the data against the approved values and the human-readable text, then grades barcodes and checks Braille on the printed proof through Hard Copy Compare, all in the same platform as your text and graphic comparison. See how it works on your own artwork.

Nathalie Martineau
Marketing Manager
Nathalie Martineau is Marketing Manager at InformaIT. She writes about proofreading, artwork verification, and the regulations that keep teams across pharma, medical devices, FMCG, and medical marketing paying close attention — whether they're navigating EU rules or US FDA requirements. When she isn't following the latest labeling update, she's helping tell the story behind Content Compare.
READ OTHER ARTICLES